Published on 2014-07-24
| Severity | Identifier / vulnerability | Technology | Signals | Age |
|---|---|---|---|---|
| CRITICAL 10.0 | CVE-2014-0607 Unrestricted file upload vulnerability in Attachmate Verastream Process Designer (VPD) before R6 SP1 Hotfix 1 allows re… | — | ||
| MEDIUM 6.9 | CVE-2014-1419 Race condition in the power policy functions in policy-funcs in acpi-support before 0.142 allows local users to gain pr… | — | ||
| MEDIUM 5.0 | CVE-2014-2360 OleumTech WIO Family Improper Input Validation | — | ||
| HIGH 7.2 | CVE-2014-2361 OleumTech WIO Family Key Management Errors | — | ||
| HIGH 7.8 | CVE-2014-2362 OleumTech WIO Use of Cryptographically Weak Pseudo-Random Number Generator | — | ||
| MEDIUM 4.6 | CVE-2014-2369 Omron NS Series HMI Cross-Site Request Forgery | — | ||
| MEDIUM 4.0 | CVE-2014-2370 Omron NS Series HMI Improper Neutralization of Input During Web Page Generation | — | ||
| HIGH 7.6 | CVE-2014-2717 Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earlier and FALCON XLWeb XLWebExe controller devices 2.02.1… | — | ||
| MEDIUM 4.3 | CVE-2014-2968 Cross-site scripting (XSS) vulnerability in the web interface on the Huawei E355 CH1E355SM modem with software 21.157.3… | — | ||
| LOW 3.5 | CVE-2014-2971 Cross-site scripting (XSS) vulnerability in AddStdLetter.jsp in MicroPact iComplaints before 8.0.2.1.8.8014 allows remo… | — | ||
| MEDIUM 4.3 | CVE-2014-3110 Multiple cross-site scripting (XSS) vulnerabilities on Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earl… | — | ||
| MEDIUM 6.1 | CVE-2014-3322 Cisco IOS XR 4.3(.2) and earlier on ASR 9000 devices does not properly perform NetFlow sampling of IP packets, which al… | — | ||
| MEDIUM 5.0 | CVE-2014-4682 The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attacker… | — | ||
| MEDIUM 4.9 | CVE-2014-4683 The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenti… | — | ||
| MEDIUM 6.0 | CVE-2014-4684 The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticate… | — | ||
| MEDIUM 4.6 | CVE-2014-4685 Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveragi… | — | ||
| MEDIUM 6.8 | CVE-2014-4686 The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a h… | — | ||
| MEDIUM 4.6 | CVE-2014-4910 Directory traversal vulnerability in tools/backlight_helper.c in X.Org xf86-video-intel 2.99.911 allows remote attacker… | — | ||
| MEDIUM 5.0 | CVE-2014-5015 bozotic HTTP server (aka bozohttpd) before 20140708, as used in NetBSD, truncates paths when checking .htpasswd restric… | — | ||
| MEDIUM 4.3 | CVE-2014-5024 Cross-site scripting (XSS) vulnerability in sgms/panelManager in Dell SonicWALL GMS, Analyzer, and UMA before 7.2 SP1 a… | — | ||
| HIGH 7.5 | CVE-2014-9097 Multiple cross-site scripting (XSS) vulnerabilities in the Apptha WordPress Video Gallery (contus-video-gallery) plugin… | — |