CVE-2014-2370
Omron NS Series HMI Improper Neutralization of Input During Web Page Generation
Mitigation
- Upgrade NS15 to 8.68x or later.
- Upgrade NS12 to 8.68x or later.
- Upgrade NS10 to 8.68x or later.
- Upgrade NS8 to 8.68x or later.
- Upgrade NS5 to 8.68x or later.
Who should check
- Anyone running Omron NS15 >= 8.1xx, < 8.68x
- Anyone running Omron NS12 >= 8.1xx, < 8.68x
- Anyone running Omron NS10 >= 8.1xx, < 8.68x
- Anyone running Omron NS8 >= 8.1xx, < 8.68x
- Anyone running Omron NS5 >= 8.1xx, < 8.68x
Vulnerability facts
- Affected
- Omron NS15 >= 8.1xx, < 8.68x; Omron NS12 >= 8.1xx, < 8.68x; Omron NS10 >= 8.1xx, < 8.68x; Omron NS8 >= 8.1xx, < 8.68x; Omron NS5 >= 8.1xx, < 8.68x
- Fixed in
- Omron NS15 8.68x, Omron NS12 8.68x, Omron NS10 8.68x, Omron NS8 8.68x, Omron NS5 8.68x
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 4.0 (v2.0, CNA)AV:N/AC:L/Au:S/C:N/I:P/A:N
Show all 6 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Authentication: Single
- Confidentiality impact: None
- Integrity impact: Partial
- Availability impact: None
- EPSS
- 1.36% chance of exploitation in 30 days (percentile 72, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2014-2370. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2014-2370.md Affected: Omron NS15 >= 8.1xx, < 8.68x; Omron NS12 >= 8.1xx, < 8.68x; Omron NS10 >= 8.1xx, < 8.68x; Omron NS8 >= 8.1xx, < 8.68x; Omron NS5 >= 8.1xx, < 8.68x Fixed in: Omron NS15 8.68x, Omron NS12 8.68x, Omron NS10 8.68x, Omron NS8 8.68x, Omron NS5 8.68x Steps: 1. Search this machine and project for Omron NS15, Omron NS12, Omron NS10, Omron NS8, Omron NS5: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2014-2370 being exploited?
There is no confirmed exploitation: CVE-2014-2370 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.36% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2014-2370?
Medium: CVSS 4.0 (v2.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2014-2370?
Omron NS15 >= 8.1xx, < 8.68x; Omron NS12 >= 8.1xx, < 8.68x; Omron NS10 >= 8.1xx, < 8.68x; Omron NS8 >= 8.1xx, < 8.68x; Omron NS5 >= 8.1xx, < 8.68x.
Is there a fix for CVE-2014-2370?
Yes. Fixed in Omron NS15 8.68x, Omron NS12 8.68x, Omron NS10 8.68x, Omron NS8 8.68x, Omron NS5 8.68x. Upgrade NS15 to 8.68x or later. Upgrade NS12 to 8.68x or later. Upgrade NS10 to 8.68x or later. Upgrade NS8 to 8.68x or later. Upgrade NS5 to 8.68x or later.
How do I check if I'm affected by CVE-2014-2370?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.