A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC BATCH V9.1 < *
  • Anyone running Siemens SIMATIC Information Server 2020 < *
  • Anyone running Siemens SIMATIC Information Server 2022 < *
  • Anyone running Siemens SIMATIC PCS 7 V9.1 < *
  • Anyone running Siemens SIMATIC Process Historian 2020 < *
  • Anyone running Siemens SIMATIC Process Historian 2022 < *
  • Anyone running Siemens SIMATIC WinCC Runtime Professional V17 < *
  • Anyone running Siemens SIMATIC WinCC Runtime Professional V18 < *

Vulnerability facts

Affected
Siemens SIMATIC BATCH V9.1 < *; Siemens SIMATIC Information Server 2020 < *; Siemens SIMATIC Information Server 2022 < *; Siemens SIMATIC PCS 7 V9.1 < *; Siemens SIMATIC Process Historian 2020 < *; Siemens SIMATIC Process Historian 2022 < *; Siemens SIMATIC WinCC Runtime Professional V17 < *; Siemens SIMATIC WinCC Runtime Professional V18 < *; Siemens SIMATIC WinCC Runtime Professional V19 < *; Siemens SIMATIC WinCC Runtime Professional V20 < *; Siemens SIMATIC WinCC Runtime Professional V21 < *; Siemens SIMATIC WinCC V7.5 < *; Siemens SIMATIC WinCC V8.0 < *; Siemens SIMATIC WinCC V8.1 < *
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: Present
  • Privileges required: None
  • User interaction: Passive
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.52% chance of exploitation in 30 days (percentile 37, 2026-11-28)
CWE
CWE-1390
Published
Modified

Description

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC BATCH V9.1< *—cvelist
Siemens SIMATIC Information Server 2020< *—cvelist
Siemens SIMATIC Information Server 2022< *—cvelist
Siemens SIMATIC PCS 7 V9.1< *—cvelist
Siemens SIMATIC Process Historian 2020< *—cvelist
Siemens SIMATIC Process Historian 2022< *—cvelist
Siemens SIMATIC WinCC Runtime Professional V17< *—cvelist
Siemens SIMATIC WinCC Runtime Professional V18< *—cvelist
Siemens SIMATIC WinCC Runtime Professional V19< *—cvelist
Siemens SIMATIC WinCC Runtime Professional V20< *—cvelist
Siemens SIMATIC WinCC Runtime Professional V21< *—cvelist
Siemens SIMATIC WinCC V7.5< *—cvelist
Siemens SIMATIC WinCC V8.0< *—cvelist
Siemens SIMATIC WinCC V8.1< *—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-58114. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-58114.md
Affected: Siemens SIMATIC BATCH V9.1 < *; Siemens SIMATIC Information Server 2020 < *; Siemens SIMATIC Information Server 2022 < *; Siemens SIMATIC PCS 7 V9.1 < *; Siemens SIMATIC Process Historian 2020 < *; Siemens SIMATIC Process Historian 2022 < *; Siemens SIMATIC WinCC Runtime Professional V17 < *; Sieme…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC BATCH V9.1, Siemens SIMATIC Information Server 2020, Siemens SIMATIC Information Server 2022, Siemens SIMATIC PCS 7 V9.1, Siemens SIMATIC Process Historian 2020, Siemens SIMATIC Process Historian 2022: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-58114 being exploited?

There is no confirmed exploitation: CVE-2026-58114 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.52% chance of exploitation in the next 30 days (as of 2026-11-28).

How serious is CVE-2026-58114?

High: CVSS 7.7 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2026-58114?

Siemens SIMATIC BATCH V9.1 < *; Siemens SIMATIC Information Server 2020 < *; Siemens SIMATIC Information Server 2022 < *; Siemens SIMATIC PCS 7 V9.1 < *; Siemens SIMATIC Process Historian 2020 < *; Siemens SIMATIC Process Historian 2022 < *; Siemens SIMATIC WinCC Runtime Professional V17 < *; Siemens SIMATIC WinCC Runtime Professional V18 < *; Siemens SIMATIC WinCC Runtime Professional V19 < *; Siemens SIMATIC WinCC Runtime Professional V20 < *; Siemens SIMATIC WinCC Runtime Professional V21 < *; Siemens SIMATIC WinCC V7.5 < *; Siemens SIMATIC WinCC V8.0 < *; Siemens SIMATIC WinCC V8.1 < *.

Is there a fix for CVE-2026-58114?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2026-58114?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

See all
Vulnerabilities, newest first
SeverityIdentifier / vulnerabilityTechnologySignalsAge
MEDIUM 5.3CVE-2026-135278

A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.24.29), Mendix Runtime V11 (All versions…

Siemens
EPSS 22%
CRITICAL 9.4CVE-2026-124981

A vulnerability has been identified in Mendix OIDC Provider (Mendix 10 compatible) (All versions < V6.0.0), Mendix OIDC…

OAuth / OIDC libraries
EPSS 24%
CRITICAL 9.2CVE-2026-121810

NGINX ngx_http_v3_module vulnerability

Nginx
EPSS 98%
CRITICAL 9.2CVE-2026-123007

NGINX ngx_http_v2_module vulnerability

Nginx+1
PoCEPSS 99%
CRITICAL 9.2CVE-2026-113425

NGINX ngx_mail_proxy_module vulnerability

Nginx
EPSS 97%
Sponsors