Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-94142

CRITICAL 9.3PoCEPSS 5%

BioStar Temperature Monitor Utility IOCTL BS_HWMIO64_W10.sys sub_1105C write-what-where

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running BioStar Temperature Monitor Utility 1.2.1806.2200

Vulnerability facts

Affected
BioStar Temperature Monitor Utility 1.2.1806.2200
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
9.3 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:POpen in CVSS calculator
Show all 12 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: Low
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: High
  • Integrity impact on other systems: High
  • Availability impact on other systems: High
  • Exploit maturity: Proof of concept
EPSS
0.18% chance of exploitation in 30 days (percentile 5, 2026-11-26)
CWE
CWE-123, CWE-119
Published
Modified

Description

A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Affected and fixed versions

Package / productAffectedFixedSource
BioStar Temperature Monitor Utility1.2.1806.2200—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-94142. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-94142.md
Affected: BioStar Temperature Monitor Utility 1.2.1806.2200
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for BioStar Temperature Monitor Utility: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-94142 being exploited?

There is no confirmed exploitation: CVE-2026-94142 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.18% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-94142?

Critical: CVSS 9.3 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2026-94142?

BioStar Temperature Monitor Utility 1.2.1806.2200.

Is there a fix for CVE-2026-94142?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2026-94142?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.