Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-9266

HIGH 7.0EPSS 0%

A Missing Required Cryptographic Step vulnerability has been identified in Moxa's embedded Linux firmware for industria…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Moxa UC-1200A Series >= 1.0, <= 1.4

Vulnerability facts

Affected
Moxa UC-1200A Series >= 1.0, <= 1.4
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.0 (v4.0, CNA)CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Physical
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.08% chance of exploitation in 30 days (percentile 0, 2026-11-26)
CWE
CWE-325
Published
Modified

Description

A Missing Required Cryptographic Step vulnerability has been identified in Moxa's embedded Linux firmware for industrial computers and controllers. This vulnerability represents an incomplete remediation of CVE-2026-0714. The firmware introduced TPM2 parameter encryption as a countermeasure against CVE-2026-0714. However, an omission in the authorization session configuration causes the parameter encryption to provide no effective protection. An attacker with invasive physical access to the device can still capture TPM communications on the SPI bus and derive the LUKS disk encryption key in plaintext. While successful exploitation results in full compromise of the encrypted disk volume, the attack requires invasive physical access, including opening the device and attaching external equipment to the SPI bus. Remote exploitation is not possible, and the attack does not affect any downstream systems.

Affected and fixed versions

Package / productAffectedFixedSource
Moxa UC-1200A Series>= 1.0, <= 1.4—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-9266. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-9266.md
Affected: Moxa UC-1200A Series >= 1.0, <= 1.4
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Moxa UC-1200A Series: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-9266 being exploited?

There is no confirmed exploitation: CVE-2026-9266 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.08% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-9266?

High: CVSS 7.0 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2026-9266?

Moxa UC-1200A Series >= 1.0, <= 1.4.

Is there a fix for CVE-2026-9266?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2026-9266?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors