CVE-2026-85497

CRITICAL 9.3EPSS 20%

CareCam CM2507 Use of Password Hash With Insufficient Computational Effort

Mitigation

  • Vendor workaround: CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.

Who should check

  • Anyone running CareCam HMT.CM2507 Firmware v251211.1507

Vulnerability facts

Affected
CareCam HMT.CM2507 Firmware v251211.1507
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.34% chance of exploitation in 30 days (percentile 20, 2026-11-26)
CWE
CWE-916
Published
Modified

Description

CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.

Affected and fixed versions

Package / productAffectedFixedSource
CareCam HMT.CM2507 Firmwarev251211.1507—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-85497. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-85497.md
Affected: CareCam HMT.CM2507 Firmware v251211.1507
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for CareCam HMT.CM2507 Firmware: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-85497 being exploited?

There is no confirmed exploitation: CVE-2026-85497 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-85497?

Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2026-85497?

CareCam HMT.CM2507 Firmware v251211.1507.

Is there a fix for CVE-2026-85497?

No fixed version is listed in the sources yet. Vendor workaround: CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.

How do I check if I'm affected by CVE-2026-85497?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors