Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-85384

HIGH 8.5EPSS 18%

Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running TP-Link Systems Inc. RE210 AC750 <= 3.14.2 Build 141218 Rel.36430n (EU); <= 3.14.2 Build 171205 Rel.71984n (US)

Vulnerability facts

Affected
TP-Link Systems Inc. RE210 AC750 <= 3.14.2 Build 141218 Rel.36430n (EU); <= 3.14.2 Build 171205 Rel.71984n (US)
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
8.5 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: High
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.32% chance of exploitation in 30 days (percentile 18, 2026-11-26)
CWE
CWE-121
Published
Modified

Description

A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution. Successful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.

Affected and fixed versions

Package / productAffectedFixedSource
TP-Link Systems Inc. RE210 AC750<= 3.14.2 Build 141218 Rel.36430n (EU); <= 3.14.2 Build 171205 Rel.71984n (US)—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-85384. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-85384.md
Affected: TP-Link Systems Inc. RE210 AC750 <= 3.14.2 Build 141218 Rel.36430n (EU); <= 3.14.2 Build 171205 Rel.71984n (US)
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for TP-Link Systems Inc. RE210 AC750: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-85384 being exploited?

There is no confirmed exploitation: CVE-2026-85384 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.32% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-85384?

High: CVSS 8.5 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2026-85384?

TP-Link Systems Inc. RE210 AC750 <= 3.14.2 Build 141218 Rel.36430n (EU); <= 3.14.2 Build 171205 Rel.71984n (US).

Is there a fix for CVE-2026-85384?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2026-85384?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors