CVE-2026-82948
RF Replay of control commands
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions
Vulnerability facts
- Affected
- Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.1 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.23% chance of exploitation in 30 days (percentile 8, 2026-11-28)
- CWE
- CWE-294
- Modified
Description
The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity. The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) | all versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-82948. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-82948.md Affected: Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-82948 being exploited?
There is no confirmed exploitation: CVE-2026-82948 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.23% chance of exploitation in the next 30 days (as of 2026-11-28).
How serious is CVE-2026-82948?
High: CVSS 7.1 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2026-82948?
Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions.
Is there a fix for CVE-2026-82948?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-82948?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.
More onyx cookware aps vulnerabilities
See all| Severity | Identifier / vulnerability | Technology | Signals | Age |
|---|---|---|---|---|
| HIGH 7.1 | CVE-2026-82950 Alert suppression through deauthentication-induced notification failure | Onyx Cookware ApS | EPSS 15% | |
| HIGH 7.1 | CVE-2026-82949 Occupancy monitoring via unencrypted RF communication | Onyx Cookware ApS | EPSS 3% |