Skip to content
FlawDB
Sign in

CVE-2026-82948

HIGH 7.1EPSS 8%

RF Replay of control commands

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions

Vulnerability facts

Affected
Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.1 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: None
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.23% chance of exploitation in 30 days (percentile 8, 2026-11-28)
CWE
CWE-294
Published
Modified

Description

The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity.  The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely.

Affected and fixed versions

Package / productAffectedFixedSource
Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system)all versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-82948. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-82948.md
Affected: Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-82948 being exploited?

There is no confirmed exploitation: CVE-2026-82948 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.23% chance of exploitation in the next 30 days (as of 2026-11-28).

How serious is CVE-2026-82948?

High: CVSS 7.1 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2026-82948?

Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) all versions.

Is there a fix for CVE-2026-82948?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2026-82948?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

See all
Vulnerabilities, newest first
SeverityIdentifier / vulnerabilityTechnologySignalsAge
HIGH 7.1CVE-2026-82950

Alert suppression through deauthentication-induced notification failure

Onyx Cookware ApS
EPSS 15%
HIGH 7.1CVE-2026-82949

Occupancy monitoring via unencrypted RF communication

Onyx Cookware ApS
EPSS 3%
Sponsors