CVE-2026-8065

CRITICAL 9.1EPSS 44%

An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions al…

Mitigation

  • Upgrade RTU500 series CMU firmware to 12.0 or later.

Who should check

  • Anyone running Hitachi Energy RTU500 series CMU firmware >= 9.0, < 12.0

Vulnerability facts

Affected
Hitachi Energy RTU500 series CMU firmware >= 9.0, < 12.0
Fixed in
Hitachi Energy RTU500 series CMU firmware 12.0
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: High
EPSS
0.62% chance of exploitation in 30 days (percentile 44, 2026-11-26)
CWE
CWE-306
Published
Modified

Description

An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to upload arbitrary firmware through a crafted POST request. Successful exploitation could allow the attacker to modify device functionality or compromise the integrity or availability of the device.

Affected and fixed versions

Package / productAffectedFixedSource
Hitachi Energy RTU500 series CMU firmware>= 9.0, < 12.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-8065. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-8065.md
Affected: Hitachi Energy RTU500 series CMU firmware >= 9.0, < 12.0
Fixed in: Hitachi Energy RTU500 series CMU firmware 12.0

Steps:
1. Search this machine and project for Hitachi Energy RTU500 series CMU firmware: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-8065 being exploited?

There is no confirmed exploitation: CVE-2026-8065 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.62% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-8065?

Critical: CVSS 9.1 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2026-8065?

Hitachi Energy RTU500 series CMU firmware >= 9.0, < 12.0.

Is there a fix for CVE-2026-8065?

Yes. Fixed in Hitachi Energy RTU500 series CMU firmware 12.0. Upgrade RTU500 series CMU firmware to 12.0 or later.

How do I check if I'm affected by CVE-2026-8065?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors