CVE-2026-80143
Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read
Mitigation
- Upgrade SLC8000 to 9.7.0.2 or later.
- Upgrade EMG8500 to 9.7.0.1 or later.
- Upgrade EMG7500 to 9.7.0.1 or later.
- Upgrade SLC9000 to 9.7.0.2 or later.
Who should check
- Anyone running LANTRONIX SLC8000 < 9.7.0.2
- Anyone running LANTRONIX EMG8500 < 9.7.0.1
- Anyone running LANTRONIX EMG7500 < 9.7.0.1
- Anyone running LANTRONIX SLB882 (versions: see the vendor advisory)
- Anyone running LANTRONIX SLCx-03 (versions: see the vendor advisory)
- Anyone running LANTRONIX SLCx-02 (versions: see the vendor advisory)
- Anyone running LANTRONIX SLC9000 < 9.7.0.2
Vulnerability facts
- Affected
- LANTRONIX SLC8000 < 9.7.0.2; LANTRONIX EMG8500 < 9.7.0.1; LANTRONIX EMG7500 < 9.7.0.1; LANTRONIX SLB882; LANTRONIX SLCx-03; LANTRONIX SLCx-02; LANTRONIX SLC9000 < 9.7.0.2
- Fixed in
- LANTRONIX SLC8000 9.7.0.2, LANTRONIX EMG8500 9.7.0.1, LANTRONIX EMG7500 9.7.0.1, LANTRONIX SLC9000 9.7.0.2
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 9.4 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 2.99% chance of exploitation in 30 days (percentile 88, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-80143. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-80143.md Affected: LANTRONIX SLC8000 < 9.7.0.2; LANTRONIX EMG8500 < 9.7.0.1; LANTRONIX EMG7500 < 9.7.0.1; LANTRONIX SLB882; LANTRONIX SLCx-03; LANTRONIX SLCx-02; LANTRONIX SLC9000 < 9.7.0.2 Fixed in: LANTRONIX SLC8000 9.7.0.2, LANTRONIX EMG8500 9.7.0.1, LANTRONIX EMG7500 9.7.0.1, LANTRONIX SLC9000 9.7.0.2 Steps: 1. Search this machine and project for LANTRONIX SLC8000, LANTRONIX EMG8500, LANTRONIX EMG7500, LANTRONIX SLB882, LANTRONIX SLCx-03, LANTRONIX SLCx-02: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Patches
FAQ
Is CVE-2026-80143 being exploited?
There is no confirmed exploitation: CVE-2026-80143 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.99% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-80143?
Critical: CVSS 9.4 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2026-80143?
LANTRONIX SLC8000 < 9.7.0.2; LANTRONIX EMG8500 < 9.7.0.1; LANTRONIX EMG7500 < 9.7.0.1; LANTRONIX SLB882; LANTRONIX SLCx-03; LANTRONIX SLCx-02; LANTRONIX SLC9000 < 9.7.0.2.
Is there a fix for CVE-2026-80143?
Yes. Fixed in LANTRONIX SLC8000 9.7.0.2, LANTRONIX EMG8500 9.7.0.1, LANTRONIX EMG7500 9.7.0.1, LANTRONIX SLC9000 9.7.0.2. Upgrade SLC8000 to 9.7.0.2 or later. Upgrade EMG8500 to 9.7.0.1 or later. Upgrade EMG7500 to 9.7.0.1 or later. Upgrade SLC9000 to 9.7.0.2 or later.
How do I check if I'm affected by CVE-2026-80143?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.