Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-7762

CRITICAL 9.8EPSS 61%

Heap buffer overflow in dot11ah.ko S1G Capabilities IE processing

Mitigation

  • Upgrade HaLowLink 2 to 2.11.13 or later.

Who should check

  • Anyone running Morse Micro HaLowLink 2 < 2.11.13

Vulnerability facts

Affected
Morse Micro HaLowLink 2 < 2.11.13
Fixed in
Morse Micro HaLowLink 2 2.11.13
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.8 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.97% chance of exploitation in 30 days (percentile 61, 2026-11-26)
Published
Modified

Description

A heap-based buffer overflow vulnerability in the dot11ah.ko HaLow Wi-Fi kernel driver in Morse Micro HaLowLink 2 software versions prior to 2.11.13 allows an unauthenticated attacker within radio range to cause a Denial of Service (kernel panic) or potentially achieve Remote Code Execution via a crafted 802.11ah beacon or probe response frame containing a malformed S1G Capabilities Information Element (IE element ID 0xD9). The function morse_dot11ah_find_s1g_caps_for_bssid() uses the IE length field directly as the size argument to memcpy without validating it against the 15-byte destination buffer. An attacker can supply up to 255 bytes, causing an overflow of up to 240 bytes of attacker-controlled data into adjacent kernel heap memory. The vulnerability is triggerable during normal scanning without authentication, association, or user interaction.

Affected and fixed versions

Package / productAffectedFixedSource
Morse Micro HaLowLink 2< 2.11.13—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-7762. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-7762.md
Affected: Morse Micro HaLowLink 2 < 2.11.13
Fixed in: Morse Micro HaLowLink 2 2.11.13

Steps:
1. Search this machine and project for Morse Micro HaLowLink 2: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-7762 being exploited?

There is no confirmed exploitation: CVE-2026-7762 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.97% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-7762?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2026-7762?

Morse Micro HaLowLink 2 < 2.11.13.

Is there a fix for CVE-2026-7762?

Yes. Fixed in Morse Micro HaLowLink 2 2.11.13. Upgrade HaLowLink 2 to 2.11.13 or later.

How do I check if I'm affected by CVE-2026-7762?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors