CVE-2026-60073
AutomationDirect Productivity Suite Out-of-bounds Read
Mitigation
- Vendor workaround: If the update cannot be applied right away, the following
- compensating controls are recommended until the upgrade can be
- performed.
- * Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure.
- * Use only trusted, dedicated internal networks or air-gapped systems for device communication.
- * Restrict both physical and logical access to authorized personnel only.
- * Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.
- * Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.
- * Enable and regularly review system logs to detect suspicious or unauthorized activity.
- * Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.
- * Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.
Who should check
- Anyone running AutomationDirect Productivity Suite <= v4.6.2.2
Vulnerability facts
- Affected
- AutomationDirect Productivity Suite <= v4.6.2.2
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.2 (v4.0, CNA)CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.24% chance of exploitation in 30 days (percentile 9, 2026-11-26)
- CWE
- CWE-125
- Modified
Description
An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| AutomationDirect Productivity Suite | <= v4.6.2.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-60073. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-60073.md Affected: AutomationDirect Productivity Suite <= v4.6.2.2 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for AutomationDirect Productivity Suite: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-60073 being exploited?
There is no confirmed exploitation: CVE-2026-60073 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.24% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-60073?
Medium: CVSS 5.2 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2026-60073?
AutomationDirect Productivity Suite <= v4.6.2.2.
Is there a fix for CVE-2026-60073?
No fixed version is listed in the sources yet. Vendor workaround: If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. * Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. * Use only trusted, dedicated internal networks or air-gapped systems for device communication. * Restrict both physical and logical access to authorized personnel only. * Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. * Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. * Enable and regularly review system logs to detect suspicious or unauthorized activity. * Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. * Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.
How do I check if I'm affected by CVE-2026-60073?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.