CVE-2026-5609
Tenda i12 Parameter wifiSSIDset formwrlSSIDset stack-based overflow
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Tenda i12 1.0.0.11(3862)
Vulnerability facts
- Affected
- Tenda i12 1.0.0.11(3862)
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:POpen in CVSS calculator
Show all 12 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- Exploit maturity: Proof of concept
- EPSS
- 1.07% chance of exploitation in 30 days (percentile 64, 2026-11-26)
- CWE
- CWE-121, CWE-119
- Modified
Description
A flaw has been found in Tenda i12 1.0.0.11(3862). Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component Parameter Handler. This manipulation of the argument index/wl_radio causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Tenda i12 | 1.0.0.11(3862) | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-5609. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-5609.md Affected: Tenda i12 1.0.0.11(3862) Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Tenda i12: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Articles
FAQ
Is CVE-2026-5609 being exploited?
There is no confirmed exploitation: CVE-2026-5609 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.07% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-5609?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2026-5609?
Tenda i12 1.0.0.11(3862).
Is there a fix for CVE-2026-5609?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-5609?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.