CVE-2026-52877
Streambert : Insecure Protocol Execution in open-external IPC Handler
Mitigation
- Upgrade streambert to 2.6.0 or later.
Who should check
- Anyone running truelockmc streambert < 2.6.0
Vulnerability facts
- Affected
- truelockmc streambert < 2.6.0
- Fixed in
- truelockmc streambert 2.6.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.3 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: Low
- EPSS
- 0.41% chance of exploitation in 30 days (percentile 27, 2026-11-26)
- CWE
- CWE-20, CWE-749
- Modified
Description
Streambert is a cross-platform Electron Desktop App to stream and download video content. Prior to version 2.6.0, the open-external IPC handler in src/ipc/downloads.js passes a renderer-supplied url directly to Electron's shell.openExternal without validating its protocol. A compromised renderer can submit file: URIs or operating-system-specific custom schemes, causing the host to open local files, access remote resources through registered handlers, or launch scripts and applications supported by those handlers. This issue is fixed in version 2.6.0.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| truelockmc streambert | < 2.6.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-52877. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-52877.md Affected: truelockmc streambert < 2.6.0 Fixed in: truelockmc streambert 2.6.0 Steps: 1. Search this machine and project for truelockmc streambert: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-52877 being exploited?
There is no confirmed exploitation: CVE-2026-52877 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.41% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-52877?
High: CVSS 8.3 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-52877?
truelockmc streambert < 2.6.0.
Is there a fix for CVE-2026-52877?
Yes. Fixed in truelockmc streambert 2.6.0. Upgrade streambert to 2.6.0 or later.
How do I check if I'm affected by CVE-2026-52877?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.