CVE-2026-48140
Unchecked enum cast vulnerability in NI grpc-device in BeginSidebandStream
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running NI grpc-device <= 2.17.0
- Anyone running NI InstrumentStudio <= 26.3.0
Vulnerability facts
- Affected
- NI grpc-device <= 2.17.0; NI InstrumentStudio <= 26.3.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.45% chance of exploitation in 30 days (percentile 31, 2026-11-26)
- CWE
- CWE-704
- Modified
Description
There is an unchecked enum cast vulnerability in NI grpc-device BeginSidebandStream that may allow an attacker to trigger invalid enum states and undefined behavior, potentially resulting in a denial of service. Successful exploitation requires an attacker to supply a specially crafted message containing an out-of-range value. This affects NI grpc-device 2.17.0 and prior versions.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-48140. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-48140.md Affected: NI grpc-device <= 2.17.0; NI InstrumentStudio <= 26.3.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for NI grpc-device, NI InstrumentStudio: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-48140 being exploited?
There is no confirmed exploitation: CVE-2026-48140 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.45% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-48140?
High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2026-48140?
NI grpc-device <= 2.17.0; NI InstrumentStudio <= 26.3.0.
Is there a fix for CVE-2026-48140?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-48140?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.