CVE-2026-47780
free5GC: UDR Improper ueId validation in free5GC EE subscription handlers allows arbitrary identifier persistence
Also known as GHSA-6gxq-gpr8-xgjp, GO-2026-5178
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Projects that depend on Go package github.com/free5gc/udr (<= 1.4.3)
- Anyone running free5gc <= 4.2.2
Vulnerability facts
- Affected
- github.com/free5gc/udr <= 1.4.3
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 6.9 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: Low
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.54% chance of exploitation in 30 days (percentile 39, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
free5GC is an open-source implementation of the 5G core network. In 4.2.3 and earlier, HandleCreateEeSubscriptions and HandleQueryeesubscriptions in free5gc/udr internal/sbi/api_datarepository.go validate the ueId path value with a regular expression whose final .+ alternative accepts every non-empty string instead of restricting identifiers to supported SUPI and GPSI formats. An actor with network reachability to the UDR SBI can submit a non-3GPP identifier to /nudr-dr/v2/subscription-data/{ueId}/context-data/ee-subscriptions, causing the identifier to pass validation and enter the normal create or query flow. The advisory does not independently establish whether authentication is required. Invalid identifiers can be persisted and retrieved as subscription records, enabling unauthorized data creation, UDR namespace pollution, persistent subscriber-metadata corruption, and interference with downstream components that trust stored identifiers to use valid 3GPP formats. The exposure is most relevant in lab, test, or loosely segmented service-based-interface deployments where direct UDR access is possible.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Go github.com/free5gc/udr | <= 1.4.3 | — | osv |
| free5gc | <= 4.2.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-47780. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-47780.md Affected: github.com/free5gc/udr <= 1.4.3 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for github.com/free5gc/udr (Go), free5gc: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-47780 being exploited?
There is no confirmed exploitation: CVE-2026-47780 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.54% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-47780?
Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-47780?
github.com/free5gc/udr <= 1.4.3.
Is there a fix for CVE-2026-47780?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-47780?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.