CVE-2026-44402
Voltronic Power SNMP Web Pro 1.1 Unauthenticated RCE via upload.cgi
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Voltronic Power SNMP Web Pro 1.1
Vulnerability facts
- Affected
- Voltronic Power SNMP Web Pro 1.1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 1.32% chance of exploitation in 30 days (percentile 71, 2026-11-26)
- CWE
- CWE-434
- Modified
Description
Voltronic Power SNMP Web Pro 1.1 contains an unauthenticated remote code execution vulnerability in the upload.cgi firmware update endpoint that allows remote attackers to execute arbitrary commands as root by uploading a crafted tar archive without valid credentials. Attackers can supply a malicious tar archive containing arbitrary executable files that are extracted to a privileged directory and executed as root, achieving full system compromise.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Voltronic Power SNMP Web Pro | 1.1 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-44402. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-44402.md Affected: Voltronic Power SNMP Web Pro 1.1 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Voltronic Power SNMP Web Pro: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2026-44402 being exploited?
There is no confirmed exploitation: CVE-2026-44402 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.32% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-44402?
Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-44402?
Voltronic Power SNMP Web Pro 1.1.
Is there a fix for CVE-2026-44402?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-44402?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.