Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-41684

MEDIUM 6.5EPSS 33%

Incus: Nil Dereferences on Restore via Malformed YAML

Also known as GHSA-x5r6-jr56-89pv, GO-2026-5742

Mitigation

  • Upgrade incus to 7.0.0 or later.

Who should check

  • Projects that depend on Go package github.com/lxc/incus/v6/cmd/incusd (<= 6.23.0)
  • Projects that depend on Go package github.com/lxc/incus
  • Projects that depend on Go package github.com/lxc/incus/v6
  • Anyone running lxc incus < 7.0.0

Vulnerability facts

Affected
github.com/lxc/incus/v6/cmd/incusd <= 6.23.0; github.com/lxc/incus; github.com/lxc/incus/v6
Fixed in
lxc incus 7.0.0
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
6.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
0.47% chance of exploitation in 30 days (percentile 33, 2026-11-26)
CWE
CWE-476
Published
Modified

Description

Incus is a system container and virtual machine manager. Prior to version 7.0.0, backup.GetInfo() trusts the inline backup/index.yaml config when present and only falls back to parsing the legacy backup/container/backup.yaml file if result.Config == nil. As a result, an archive can carry a valid inline config that passes the initial import preflight while also carrying a malformed legacy backup/container/backup.yaml file that is reparsed later from the restored file system. ParseConfigYamlFile() accepts YAML documents with no container section, and multiple downstream consumers then dereference. Container without checking for nil. Confirmed examples in the instance restore and import flow include backup.UpdateInstanceConfig() and internalImportFromBackup(). An authenticated user with permission to import instance backups may be able to crash the Incus daemon with a crafted backup archive whose inline backup/index.yaml is valid but whose extracted legacy backup.yaml omits container. The crash occurs in the restore path after archive extraction has begun. This issue has been patched in version 7.0.0.

Affected and fixed versions

Package / productAffectedFixedSource
Go github.com/lxc/incus/v6/cmd/incusd<= 6.23.0—osv
Go github.com/lxc/incus——osv
Go github.com/lxc/incus/v6——osv
lxc incus< 7.0.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-41684. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-41684.md
Affected: github.com/lxc/incus/v6/cmd/incusd <= 6.23.0; github.com/lxc/incus; github.com/lxc/incus/v6
Fixed in: lxc incus 7.0.0

Steps:
1. Search this machine and project for github.com/lxc/incus/v6/cmd/incusd (Go), github.com/lxc/incus (Go), github.com/lxc/incus/v6 (Go), lxc incus: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-41684 being exploited?

There is no confirmed exploitation: CVE-2026-41684 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.47% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-41684?

Medium: CVSS 6.5 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2026-41684?

github.com/lxc/incus/v6/cmd/incusd <= 6.23.0; github.com/lxc/incus; github.com/lxc/incus/v6.

Is there a fix for CVE-2026-41684?

Yes. Fixed in lxc incus 7.0.0. Upgrade incus to 7.0.0 or later.

How do I check if I'm affected by CVE-2026-41684?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors