CVE-2026-41502
BACnet Stack: Off-by-One Out-of-Bounds Read in ReadPropertyMultiple Object ID Decoder
Mitigation
- Upgrade bacnet-stack to 1.4.3 or later.
Who should check
- Anyone running bacnet-stack >= 1.4.0, < 1.4.3
Vulnerability facts
- Affected
- bacnet-stack >= 1.4.0, < 1.4.3
- Fixed in
- bacnet-stack 1.4.3
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.62% chance of exploitation in 30 days (percentile 44, 2026-11-26)
- CWE
- CWE-125, CWE-193
- Modified
Description
BACnet Stack is a BACnet open source protocol stack C library for embedded systems. Prior to 1.4.3, an off-by-one out-of-bounds read vulnerability in bacnet-stack's ReadPropertyMultiple service decoder allows unauthenticated remote attackers to read one byte past an allocated buffer boundary by sending a crafted RPM request with a truncated object identifier. The vulnerability is in rpm_decode_object_id(), which checks apdu_len < 5 but then accesses all 6 byte positions (indices 0-5) — consuming 1 byte for the context tag, 4 bytes for the object ID, then reading apdu[5] for the opening tag check. A 5-byte input passes the length check but causes a 1-byte OOB read, leading to crashes on embedded BACnet devices. The vulnerability exists in src/bacnet/rpm.c and affects any deployment that enables the ReadPropertyMultiple confirmed service handler (enabled by default in the reference server). This vulnerability is fixed in 1.4.3.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| bacnet-stack | >= 1.4.0, < 1.4.3 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-41502. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-41502.md Affected: bacnet-stack >= 1.4.0, < 1.4.3 Fixed in: bacnet-stack 1.4.3 Steps: 1. Search this machine and project for bacnet-stack: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-41502 being exploited?
There is no confirmed exploitation: CVE-2026-41502 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.62% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-41502?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-41502?
bacnet-stack >= 1.4.0, < 1.4.3.
Is there a fix for CVE-2026-41502?
Yes. Fixed in bacnet-stack 1.4.3. Upgrade bacnet-stack to 1.4.3 or later.
How do I check if I'm affected by CVE-2026-41502?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.