Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-40906

CRITICAL 10.0EPSS 40%

Electric: SQL Injection via ORDER BY Parameter in Shape API

Mitigation

  • Upgrade electric to 1.5.0 or later.

Who should check

  • Anyone running electric-sql electric >= 1.1.12, < 1.5.0

Vulnerability facts

Affected
electric-sql electric >= 1.1.12, < 1.5.0
Fixed in
electric-sql electric 1.5.0
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
10.0 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.55% chance of exploitation in 30 days (percentile 40, 2026-11-26)
CWE
CWE-89
Published
Modified

Description

Electric is a Postgres sync engine. From 1.1.12 to before 1.5.0, the order_by parameter in the ElectricSQL /v1/shape API is vulnerable to error-based SQL injection, allowing any authenticated user to read, write, and destroy the full contents of the underlying PostgreSQL database through crafted ORDER BY expressions. This vulnerability is fixed in 1.5.0.

Affected and fixed versions

Package / productAffectedFixedSource
electric-sql electric>= 1.1.12, < 1.5.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-40906. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-40906.md
Affected: electric-sql electric >= 1.1.12, < 1.5.0
Fixed in: electric-sql electric 1.5.0

Steps:
1. Search this machine and project for electric-sql electric: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-40906 being exploited?

There is no confirmed exploitation: CVE-2026-40906 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.55% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-40906?

Critical: CVSS 10.0 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2026-40906?

electric-sql electric >= 1.1.12, < 1.5.0.

Is there a fix for CVE-2026-40906?

Yes. Fixed in electric-sql electric 1.5.0. Upgrade electric to 1.5.0 or later.

How do I check if I'm affected by CVE-2026-40906?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors