# CVE-2026-3559: Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.1
- **CVSS:** 8.1 (v3.0, CNA) `CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.53% (percentile 38, 2026-11-26)
- **CWE:** CWE-323
- **Published:** 2026-03-13T20:36:57.441Z
- **Modified:** 2026-06-17T10:43:47.230Z

## Who should check

- Anyone running Philips Hue Bridge 1.73.1973146020

## Description

Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.

## Affected and fixed versions

- Philips Hue Bridge: 1.73.1973146020 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2026-3559. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-3559.md
Affected: Philips Hue Bridge 1.73.1973146020
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Philips Hue Bridge: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2026-3559 being exploited?

There is no confirmed exploitation: CVE-2026-3559 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.53% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2026-3559?

High: CVSS 8.1 (v3.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2026-3559?

Philips Hue Bridge 1.73.1973146020.

### Is there a fix for CVE-2026-3559?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2026-3559?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.zerodayinitiative.com/advisories/ZDI-26-157/>