Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2026-35383

MEDIUM 6.9EPSS 37%

Bentley Systems iTwin Platform exposed access token

Mitigation

  • Upgrade iTwin Platform to 2026-03-27 or later.

Who should check

  • Anyone running Bentley Systems iTwin Platform < 2026-03-27

Vulnerability facts

Affected
Bentley Systems iTwin Platform < 2026-03-27
Fixed in
Bentley Systems iTwin Platform 2026-03-27
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
6.9 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: Low
  • Integrity impact: None
  • Availability impact: Low
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.51% chance of exploitation in 30 days (percentile 37, 2026-11-26)
CWE
CWE-540
Published
Modified

Description

Bentley Systems iTwin Platform exposed a Cesium ion access token in the source of some web pages. An unauthenticated attacker could use this token to enumerate or delete certain assets. As of 2026-03-27, the token is no longer present in the web pages and cannot be used to enumerate or delete assets.

Affected and fixed versions

Package / productAffectedFixedSource
Bentley Systems iTwin Platform< 2026-03-27—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-35383. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-35383.md
Affected: Bentley Systems iTwin Platform < 2026-03-27
Fixed in: Bentley Systems iTwin Platform 2026-03-27

Steps:
1. Search this machine and project for Bentley Systems iTwin Platform: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-35383 being exploited?

There is no confirmed exploitation: CVE-2026-35383 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.51% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-35383?

Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2026-35383?

Bentley Systems iTwin Platform < 2026-03-27.

Is there a fix for CVE-2026-35383?

Yes. Fixed in Bentley Systems iTwin Platform 2026-03-27. Upgrade iTwin Platform to 2026-03-27 or later.

How do I check if I'm affected by CVE-2026-35383?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.