CVE-2026-34021
Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay
Mitigation
- Vendor workaround: Physically isolate all SafeController devices so that only authorized personnel can access them. Harden all connected systems that communicate via the serial interface, disable unnecessary services, and restrict access to authorized personnel only. Ensure that servers communicating with SafeController devices use strong, unique authentication credentials and are not accessible to unauthorized users. Maintain physical security of all interconnected components to prevent unauthorized access or tampering.
Who should check
- Anyone running Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320
Vulnerability facts
- Affected
- Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.6 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.25% chance of exploitation in 30 days (percentile 10, 2026-11-26)
- CWE
- CWE-294
- Modified
Description
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) | Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-34021. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-34021.md Affected: Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-34021 being exploited?
There is no confirmed exploitation: CVE-2026-34021 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.25% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-34021?
High: CVSS 8.6 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2026-34021?
Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320.
Is there a fix for CVE-2026-34021?
No fixed version is listed in the sources yet. Vendor workaround: Physically isolate all SafeController devices so that only authorized personnel can access them. Harden all connected systems that communicate via the serial interface, disable unnecessary services, and restrict access to authorized personnel only. Ensure that servers communicating with SafeController devices use strong, unique authentication credentials and are not accessible to unauthorized users. Maintain physical security of all interconnected components to prevent unauthorized access or tampering.
How do I check if I'm affected by CVE-2026-34021?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.