CVE-2026-3055
Insufficient input validation leading to memory overread
Mitigation
- Upgrade ADC to 37.262 or later.
- Upgrade Gateway to 62.23 or later.
Who should check
- Anyone running NetScaler ADC >= 14.1, < 66.59; >= 13.1, < 62.23; >= 13.1 FIPS and NDcPP, < 37.262
- Anyone running NetScaler Gateway >= 14.1, < 66.59; >= 13.1, < 62.23
Vulnerability facts
- Affected
- NetScaler ADC >= 14.1, < 66.59; >= 13.1, < 62.23; >= 13.1 FIPS and NDcPP, < 37.262; NetScaler Gateway >= 14.1, < 66.59; >= 13.1, < 62.23
- Fixed in
- NetScaler ADC 66.59, NetScaler ADC 62.23, NetScaler ADC 37.262, NetScaler Gateway 66.59, NetScaler Gateway 62.23
- Exploited in the wild
- Yes: in CISA KEV since 2026-03-30; federal due date 2026-04-02
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:LOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: Low
- EPSS
- 4.51% chance of exploitation in 30 days (percentile 92, 2026-11-26)
- CWE
- CWE-125
- Modified
Description
Insufficient input validation in NetScaler ADC and NetScaler Gateway when configured as a SAML IDP leading to memory overread
Affected and fixed versions
Timeline
- 2026-03-23 Published
- 2026-03-30 Added to CISA KEV (exploited in the wild)
- 2026-04-02 CISA remediation due date for US federal agencies
- 2026-06-17 Last modified
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-3055. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-3055.md Affected: NetScaler ADC >= 14.1, < 66.59; >= 13.1, < 62.23; >= 13.1 FIPS and NDcPP, < 37.262; NetScaler Gateway >= 14.1, < 66.59; >= 13.1, < 62.23 Fixed in: NetScaler ADC 66.59, NetScaler ADC 62.23, NetScaler ADC 37.262, NetScaler Gateway 66.59, NetScaler Gateway 62.23 Steps: 1. Search this machine and project for NetScaler ADC, NetScaler Gateway: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2026-3055 being exploited?
Yes. CISA lists CVE-2026-3055 in its Known Exploited Vulnerabilities catalog since 2026-03-30, which means attacks have been seen. Public exploit code or a proof of concept is available. EPSS estimates a 4.51% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-3055?
Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-3055?
NetScaler ADC >= 14.1, < 66.59; >= 13.1, < 62.23; >= 13.1 FIPS and NDcPP, < 37.262; NetScaler Gateway >= 14.1, < 66.59; >= 13.1, < 62.23.
Is there a fix for CVE-2026-3055?
Yes. Fixed in NetScaler ADC 66.59, NetScaler ADC 62.23, NetScaler ADC 37.262, NetScaler Gateway 66.59, NetScaler Gateway 62.23. Upgrade ADC to 37.262 or later. Upgrade Gateway to 62.23 or later.
How do I check if I'm affected by CVE-2026-3055?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.