CVE-2026-19321
Power System Integer Overflow
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running IBM Power Systems Firmware FW1120.00; >= FW1110.00, <= FW1110.30; >= FW1060.00, <= FW1060.80
Vulnerability facts
- Affected
- IBM Power Systems Firmware FW1120.00; >= FW1110.00, <= FW1110.30; >= FW1060.00, <= FW1060.80
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.7 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: Low
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.16% chance of exploitation in 30 days (percentile 2, 2026-11-26)
- CWE
- CWE-190
- Modified
Description
Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the host firmware. An attacker with service access to the service processor can supply a carefully crafted command that could leak the contents of hardware registers that should be inaccessible to the service processor. Successful exploitation could result in limited confidentiality or availability impacts to the affected host system.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| IBM Power Systems Firmware | FW1120.00; >= FW1110.00, <= FW1110.30; >= FW1060.00, <= FW1060.80 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-19321. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-19321.md Affected: IBM Power Systems Firmware FW1120.00; >= FW1110.00, <= FW1110.30; >= FW1060.00, <= FW1060.80 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for IBM Power Systems Firmware: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-19321 being exploited?
There is no confirmed exploitation: CVE-2026-19321 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.16% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-19321?
Medium: CVSS 6.7 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2026-19321?
IBM Power Systems Firmware FW1120.00; >= FW1110.00, <= FW1110.30; >= FW1060.00, <= FW1060.80.
Is there a fix for CVE-2026-19321?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-19321?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.