CVE-2026-120295
Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware
Mitigation
- Upgrade nerves_hub_web to 2.5.3 or later.
Who should check
- Anyone running nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3
- Anyone running nerves-hub nerves_hub_web >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa; >= adaeefdb7a835525482588f43332ef988cc448c7, < *
Vulnerability facts
- Affected
- nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa; >= adaeefdb7a835525482588f43332ef988cc448c7, < *
- Fixed in
- nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: Low
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.33% chance of exploitation in 30 days (percentile 18, 2026-11-28)
- CWE
- CWE-863
- Modified
Description
Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| nerves-hub nerves_hub_web | >= 1.0.0, < 2.5.3 | — | cvelist |
| nerves-hub nerves_hub_web | >= 1.0.0, < 2.5.3 | — | cvelist |
| nerves-hub nerves_hub_web | >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa; >= adaeefdb7a835525482588f43332ef988cc448c7, < * | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-120295. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-120295.md Affected: nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa; >= adaeefdb7a835525482588f43332ef988cc448c7, < * Fixed in: nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa Steps: 1. Search this machine and project for nerves-hub nerves_hub_web: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Patches
FAQ
Is CVE-2026-120295 being exploited?
There is no confirmed exploitation: CVE-2026-120295 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.33% chance of exploitation in the next 30 days (as of 2026-11-28).
How serious is CVE-2026-120295?
High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2026-120295?
nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 1.0.0, < 2.5.3; nerves-hub nerves_hub_web >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa; >= adaeefdb7a835525482588f43332ef988cc448c7, < *.
Is there a fix for CVE-2026-120295?
Yes. Fixed in nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 2.5.3, nerves-hub nerves_hub_web 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa. Upgrade nerves_hub_web to 2.5.3 or later.
How do I check if I'm affected by CVE-2026-120295?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.
More nerves-hub vulnerabilities
See all| Severity | Identifier / vulnerability | Technology | Signals | Age |
|---|---|---|---|---|
| HIGH 8.2 | CVE-2026-125275 A device certificate whose CA isn't registered can keep a TLS handshake running forever | nerves-hub | EPSS 38% | |
| CRITICAL 9.4 | CVE-2026-119446 Session fixation in the CLI login flow allows an unauthenticated attacker to obtain a user's API token | nerves-hub | EPSS 48% | |
| MEDIUM 5.3 | CVE-2026-120286 Missing authorization in device and deployment group page events allows view-role members to change devices and deployment groups | nerves-hub | EPSS 14% | |
| LOW 2.3 | CVE-2026-120997 Improper session invalidation keeps removed or demoted members' open pages and device consoles working at their old role | nerves-hub | EPSS 32% | |
| HIGH 8.6 | CVE-2026-120730 Mass assignment of organization, product and deployment group IDs allows users to write into other organizations and receive their firmware | nerves-hub | EPSS 36% |