CVE-2026-119739
Amlogic DroidLogic SubTitleService Out-of-Bounds Write via VobSub SET_CONTR
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Nexbox A95X NEXBOX-A95X-AP6330
- Anyone running Amlogic Android SDK (versions: see the vendor advisory)
Vulnerability facts
- Affected
- Nexbox A95X NEXBOX-A95X-AP6330; Amlogic Android SDK
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 6.9 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.51% chance of exploitation in 30 days (percentile 37, 2026-11-26)
- CWE
- CWE-787
- Modified
Description
The VobSub subtitle decoder libsub_vob (part of the Amlogic DroidLogic SubTitleService), as shipped on Nexbox A95X (Amlogic S905X) TV boxes, contains an out-of-bounds write vulnerability in vob_fill_pixel() that allows remote attackers to corrupt stack memory by sending a crafted SET_CONTR command with an attacker-controlled alpha value that drives an unbounded array index (change_data) past the end of the fixed four-element PixelDatas array. Attackers can exploit this by sending malicious VobSub data over the unauthenticated tcp/10100 socket or via a malicious .sub file to zero out adjacent stack bytes, resulting in silent stack corruption or process crash.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Nexbox A95X | NEXBOX-A95X-AP6330 | — | cvelist |
| Amlogic Android SDK | — | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-119739. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-119739.md Affected: Nexbox A95X NEXBOX-A95X-AP6330; Amlogic Android SDK Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Nexbox A95X, Amlogic Android SDK: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2026-119739 being exploited?
There is no confirmed exploitation: CVE-2026-119739 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.51% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-119739?
Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-119739?
Nexbox A95X NEXBOX-A95X-AP6330; Amlogic Android SDK.
Is there a fix for CVE-2026-119739?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-119739?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.