# CVE-2026-119055: CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could tri…

- **Severity:** MEDIUM 4.6
- **CVSS:** 4.6 (v4.0, CNA) `CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: Active; Confidentiality impact: Low; Integrity impact: Low; Availability impact: Low; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.18% (percentile 4, 2026-11-28)
- **CWE:** CWE-416
- **Published:** 2026-11-11T18:28:11.702Z
- **Modified:** 2026-11-16T19:17:26.320Z

## Who should check

- Anyone running Schneider Electric EcoStruxure™ Power Build Rapsody FR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior

## Description

CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could trick the end user to open a specially crafted malicious SSD file.

## Affected and fixed versions

- Schneider Electric EcoStruxure™ Power Build Rapsody: FR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2026-119055. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-119055.md
Affected: Schneider Electric EcoStruxure™ Power Build Rapsody FR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric EcoStruxure™ Power Build Rapsody: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2026-119055 being exploited?

There is no confirmed exploitation: CVE-2026-119055 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.18% chance of exploitation in the next 30 days (as of 2026-11-28).

### How serious is CVE-2026-119055?

Medium: CVSS 4.6 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2026-119055?

Schneider Electric EcoStruxure™ Power Build Rapsody FR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior.

### Is there a fix for CVE-2026-119055?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2026-119055?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-314-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-314-01.pdf>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2026-119055>
- FIRST EPSS: EPSS scores by FIRST <https://www.first.org/epss/>

HTML: <https://flawdb.com/CVE-2026-119055> · JSON: <https://flawdb.com/api/v1/entries/CVE-2026-119055>