CVE-2026-118461
AIS PersonnelService client performs unauthenticated doctor-specific operations
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running CompuGroup Medical Infantia <= 1.10.0
- Anyone running CompuGroup Medical Profim <= 1.10.0
- Anyone running CompuGroup Medical Venere <= 1.10.0
- Anyone running CompuGroup Medical Phronesis <= 1.10.0
Vulnerability facts
- Affected
- CompuGroup Medical Infantia <= 1.10.0; CompuGroup Medical Profim <= 1.10.0; CompuGroup Medical Venere <= 1.10.0; CompuGroup Medical Phronesis <= 1.10.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.0 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:UOpen in CVSS calculator
Show all 12 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- Exploit maturity: Unreported
- EPSS
- 0.56% chance of exploitation in 30 days (percentile 41, 2026-11-26)
- CWE
- CWE-306
- Modified
Description
The shared client accepts caller-controlled doctor identifiers for read and write operations without requiring authentication or authorization credentials.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| CompuGroup Medical Infantia | <= 1.10.0 | — | cvelist |
| CompuGroup Medical Profim | <= 1.10.0 | — | cvelist |
| CompuGroup Medical Venere | <= 1.10.0 | — | cvelist |
| CompuGroup Medical Phronesis | <= 1.10.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-118461. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-118461.md Affected: CompuGroup Medical Infantia <= 1.10.0; CompuGroup Medical Profim <= 1.10.0; CompuGroup Medical Venere <= 1.10.0; CompuGroup Medical Phronesis <= 1.10.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for CompuGroup Medical Infantia, CompuGroup Medical Profim, CompuGroup Medical Venere, CompuGroup Medical Phronesis: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-118461 being exploited?
There is no confirmed exploitation: CVE-2026-118461 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.56% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-118461?
High: CVSS 8.0 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-118461?
CompuGroup Medical Infantia <= 1.10.0; CompuGroup Medical Profim <= 1.10.0; CompuGroup Medical Venere <= 1.10.0; CompuGroup Medical Phronesis <= 1.10.0.
Is there a fix for CVE-2026-118461?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2026-118461?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.