CVE-2026-116570
FreeSWITCH: Pre-authentication stack buffer overflow in mod_xml_rpc HTTP directory authentication
Mitigation
- Upgrade freeswitch to 1.11.2 or later.
Who should check
- Anyone running signalwire freeswitch < 1.11.2
Vulnerability facts
- Affected
- signalwire freeswitch < 1.11.2
- Fixed in
- signalwire freeswitch 1.11.2
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.99% chance of exploitation in 30 days (percentile 62, 2026-11-26)
- CWE
- CWE-121, CWE-131, CWE-787
- Modified
Description
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, http_directory_auth() rebuilt an expected user@domain:password credential and base64-encoded it into an 80-byte buffer using an encoder without an output-length argument. A configured credential longer than 57 characters overflowed the stack before the supplied HTTP Basic password was compared. An unauthenticated client only needed to name an existing directory user on an exposed mod_xml_rpc HTTP listener; the module is built but not loaded by the stock configuration. The overflow can corrupt the stack and crash FreeSWITCH, ending every active call, although the overrun bytes come from the configured credential and remote code execution has not been demonstrated. This issue is fixed in version 1.11.2.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| signalwire freeswitch | < 1.11.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-116570. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-116570.md Affected: signalwire freeswitch < 1.11.2 Fixed in: signalwire freeswitch 1.11.2 Steps: 1. Search this machine and project for signalwire freeswitch: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-116570 being exploited?
There is no confirmed exploitation: CVE-2026-116570 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.99% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-116570?
High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-116570?
signalwire freeswitch < 1.11.2.
Is there a fix for CVE-2026-116570?
Yes. Fixed in signalwire freeswitch 1.11.2. Upgrade freeswitch to 1.11.2 or later.
How do I check if I'm affected by CVE-2026-116570?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.