CVE-2026-112172
Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure
Mitigation
- Upgrade XDent to 4.4.0 or later.
- Upgrade XMedical to 4.4.0 or later.
Who should check
- Anyone running CompuGroup Medical XDent < 4.4.0
- Anyone running CompuGroup Medical XMedical < 4.4.0
Vulnerability facts
- Affected
- CompuGroup Medical XDent < 4.4.0; CompuGroup Medical XMedical < 4.4.0
- Fixed in
- CompuGroup Medical XDent 4.4.0, CompuGroup Medical XMedical 4.4.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/AU:YOpen in CVSS calculator
Show all 13 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- Exploit maturity: Unreported
- AU: Y
- EPSS
- 0.52% chance of exploitation in 30 days (percentile 37, 2026-11-26)
- CWE
- CWE-89
- Modified
Description
CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| CompuGroup Medical XDent | < 4.4.0 | — | cvelist |
| CompuGroup Medical XMedical | < 4.4.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2026-112172. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2026-112172.md Affected: CompuGroup Medical XDent < 4.4.0; CompuGroup Medical XMedical < 4.4.0 Fixed in: CompuGroup Medical XDent 4.4.0, CompuGroup Medical XMedical 4.4.0 Steps: 1. Search this machine and project for CompuGroup Medical XDent, CompuGroup Medical XMedical: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2026-112172 being exploited?
There is no confirmed exploitation: CVE-2026-112172 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.52% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2026-112172?
High: CVSS 8.1 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2026-112172?
CompuGroup Medical XDent < 4.4.0; CompuGroup Medical XMedical < 4.4.0.
Is there a fix for CVE-2026-112172?
Yes. Fixed in CompuGroup Medical XDent 4.4.0, CompuGroup Medical XMedical 4.4.0. Upgrade XDent to 4.4.0 or later. Upgrade XMedical to 4.4.0 or later.
How do I check if I'm affected by CVE-2026-112172?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.