# CVE-2026-0652: Remote Code Execution on TP-Link Tapo C260 by Guest User

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.7
- **CVSS:** 8.7 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: Low; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: Low; Integrity impact on other systems: Low; Availability impact on other systems: Low
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, login needed
- **EPSS:** 3.37% (percentile 90, 2026-11-26)
- **CWE:** CWE-78
- **Published:** 2026-02-10T17:27:42.953Z
- **Modified:** 2026-06-17T10:11:09.110Z

## Who should check

- Anyone running TP-Link Systems Inc. Tapo C260 v1 \< 1.1.9 Build 251226 Rel.55870n

## Description

On TP-Link Tapo C260 v1, command injection vulnerability exists due to improper sanitization in certain POST parameters during configuration synchronization. An authenticated attacker can execute arbitrary system commands with high impact on confidentiality, integrity and availability. It may cause full device compromise.

## Affected and fixed versions

- TP-Link Systems Inc. Tapo C260 v1: \< 1.1.9 Build 251226 Rel.55870n (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2026-0652. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-0652.md
Affected: TP-Link Systems Inc. Tapo C260 v1 < 1.1.9 Build 251226 Rel.55870n
Fixed in: TP-Link Systems Inc. Tapo C260 v1 1.1.9

Steps:
1. Search this machine and project for TP-Link Systems Inc. Tapo C260 v1: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2026-0652 being exploited?

There is no confirmed exploitation: CVE-2026-0652 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.37% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2026-0652?

High: CVSS 8.7 (v4.0, scored by CNA). Remote, login needed.

### Which versions are affected by CVE-2026-0652?

TP-Link Systems Inc. Tapo C260 v1 \< 1.1.9 Build 251226 Rel.55870n.

### Is there a fix for CVE-2026-0652?

Yes. Fixed in TP-Link Systems Inc. Tapo C260 v1 1.1.9. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2026-0652?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://www.tp-link.com/us/support/faq/4960/>
- patch: <https://www.tp-link.com/us/support/download/tapo-c260/v1/>
- patch: <https://www.tp-link.com/en/support/download/tapo-c260/v1/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2026-0652>

HTML: <https://flawdb.com/CVE-2026-0652> · JSON: <https://flawdb.com/api/v1/entries/CVE-2026-0652>
