CVE-2025-9997
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric Saitel DR RTU >= all versions, <= 11.06.29
- Anyone running Schneider Electric Saitel DP RTU >= all versions, <= 11.06.33
Vulnerability facts
- Affected
- Schneider Electric Saitel DR RTU >= all versions, <= 11.06.29; Schneider Electric Saitel DP RTU >= all versions, <= 11.06.33
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.8 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Attack requirements: Present
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: Low
- Availability impact: Low
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.89% chance of exploitation in 30 days (percentile 57, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric Saitel DR RTU | >= all versions, <= 11.06.29 | — | cvelist |
| Schneider Electric Saitel DP RTU | >= all versions, <= 11.06.33 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-9997. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-9997.md Affected: Schneider Electric Saitel DR RTU >= all versions, <= 11.06.29; Schneider Electric Saitel DP RTU >= all versions, <= 11.06.33 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric Saitel DR RTU, Schneider Electric Saitel DP RTU: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-9997 being exploited?
There is no confirmed exploitation: CVE-2025-9997 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.89% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-9997?
Medium: CVSS 5.8 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-9997?
Schneider Electric Saitel DR RTU >= all versions, <= 11.06.29; Schneider Electric Saitel DP RTU >= all versions, <= 11.06.33.
Is there a fix for CVE-2025-9997?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-9997?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.