# CVE-2025-9696: Use of Hard-coded Credentials in SunPower PVS6

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.4
- **CVSS:** 9.4 (v4.0, CNA) `CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: High; Integrity impact on other systems: High; Availability impact on other systems: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.17% (percentile 4, 2026-11-26)
- **CWE:** CWE-798
- **Published:** 2025-09-02T16:34:35.362Z
- **Modified:** 2026-06-17T10:09:33.257Z

## Who should check

- Anyone running SunPower PVS6 \<= 2025.06 build 61839

## Description

The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices.

## Affected and fixed versions

- SunPower PVS6: \<= 2025.06 build 61839 (cvelist)

## Mitigation

- Vendor workaround: SunPower did not respond to CISA's attempt to coordinate these vulnerabilities. Users should contact  SunPower https://us.sunpower.com/contact-us  for more information.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-9696. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-9696.md
Affected: SunPower PVS6 <= 2025.06 build 61839
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for SunPower PVS6: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-9696 being exploited?

There is no confirmed exploitation: CVE-2025-9696 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.17% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-9696?

Critical: CVSS 9.4 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-9696?

SunPower PVS6 \<= 2025.06 build 61839.

### Is there a fix for CVE-2025-9696?

No fixed version is listed in the sources yet. Vendor workaround: SunPower did not respond to CISA's attempt to coordinate these vulnerabilities. Users should contact  SunPower https://us.sunpower.com/contact-us  for more information.

### How do I check if I'm affected by CVE-2025-9696?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-advisories/icsa-25-245-03>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-9696>

HTML: <https://flawdb.com/CVE-2025-9696> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-9696>