CVE-2025-9674
Transbyte Scooper News App com.hatsune.eagleee AndroidManifest.xml improper export of android application components
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Transbyte Scooper News App 1.0; 1.1; 1.2
Vulnerability facts
- Affected
- Transbyte Scooper News App 1.0; 1.1; 1.2
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 4.8 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:POpen in CVSS calculator
Show all 12 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: Low
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- Exploit maturity: Proof of concept
- EPSS
- 0.34% chance of exploitation in 30 days (percentile 21, 2026-11-26)
- CWE
- CWE-926
- Modified
Description
A flaw has been found in Transbyte Scooper News App up to 1.2 on Android. Affected by this issue is some unknown functionality of the file AndroidManifest.xml of the component com.hatsune.eagleee. This manipulation causes improper export of android application components. The attack requires local access. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Transbyte Scooper News App | 1.0; 1.1; 1.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-9674. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-9674.md Affected: Transbyte Scooper News App 1.0; 1.1; 1.2 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Transbyte Scooper News App: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2025-9674 being exploited?
There is no confirmed exploitation: CVE-2025-9674 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-9674?
Medium: CVSS 4.8 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-9674?
Transbyte Scooper News App 1.0; 1.1; 1.2.
Is there a fix for CVE-2025-9674?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-9674?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.