# CVE-2025-9495: Viessmann Vitogate 300 Authentication Bypass

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.7
- **CVSS:** 8.7 (v4.0, CNA) `CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.33% (percentile 18, 2026-11-26)
- **CWE:** CWE-602
- **Published:** 2025-09-23T01:16:53.619Z
- **Modified:** 2026-10-11T20:10:00.200Z

## Who should check

- Anyone running Viessmann Vitogate 300 \>= 1, \< 3.0.0.0

## Description

The Vitogate 300 web interface fails to enforce proper server-side authentication and relies on frontend-based authentication controls. This allows an attacker to simply modify HTML elements in the browser’s developer tools to bypass login restrictions. By removing specific UI elements, an attacker can reveal the hidden administration menu, giving them full control over the device.

## Affected and fixed versions

- Viessmann Vitogate 300: \>= 1, \< 3.0.0.0 (cvelist)

## Mitigation

- Upgrade Vitogate 300 to 3.0.0.0 or later.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-9495. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-9495.md
Affected: Viessmann Vitogate 300 >= 1, < 3.0.0.0
Fixed in: Viessmann Vitogate 300 3.0.0.0

Steps:
1. Search this machine and project for Viessmann Vitogate 300: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-9495 being exploited?

There is no confirmed exploitation: CVE-2025-9495 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.33% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-9495?

High: CVSS 8.7 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-9495?

Viessmann Vitogate 300 \>= 1, \< 3.0.0.0.

### Is there a fix for CVE-2025-9495?

Yes. Fixed in Viessmann Vitogate 300 3.0.0.0. Upgrade Vitogate 300 to 3.0.0.0 or later.

### How do I check if I'm affected by CVE-2025-9495?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://https//www.corporate.carrier.com/product-security/advisories-resources/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-9495>

HTML: <https://flawdb.com/CVE-2025-9495> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-9495>