Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2025-8979

HIGH 7.5PoCEPSS 46%

Tenda AC15 Firmware Update check_fw data authenticity

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Tenda AC15 15.13.07.13

Vulnerability facts

Affected
Tenda AC15 15.13.07.13
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, login needed
CVSS
7.5 (v4.0, CNA)CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:POpen in CVSS calculator
Show all 12 CVSS metrics
  • Attack vector: Network
  • Attack complexity: High
  • Attack requirements: None
  • Privileges required: High
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
  • Exploit maturity: Proof of concept
EPSS
0.65% chance of exploitation in 30 days (percentile 46, 2026-11-26)
CWE
CWE-345
Published
Modified

Description

A vulnerability was identified in Tenda AC15 15.13.07.13. Affected by this vulnerability is the function check_fw_type/split_fireware/check_fw of the component Firmware Update Handler. The manipulation leads to insufficient verification of data authenticity. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.

Affected and fixed versions

Package / productAffectedFixedSource
Tenda AC1515.13.07.13—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2025-8979. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-8979.md
Affected: Tenda AC15 15.13.07.13
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Tenda AC15: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2025-8979 being exploited?

There is no confirmed exploitation: CVE-2025-8979 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.65% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2025-8979?

High: CVSS 7.5 (v4.0, scored by CNA). Remote, login needed. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2025-8979?

Tenda AC15 15.13.07.13.

Is there a fix for CVE-2025-8979?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2025-8979?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors