CVE-2025-7909
D-Link DIR-513 Boa Webserver formLanSetupRouterSettings sprintf stack-based overflow
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running D-Link DIR-513 1.0
Vulnerability facts
- Affected
- D-Link DIR-513 1.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:POpen in CVSS calculator
Show all 12 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- Exploit maturity: Proof of concept
- EPSS
- 2.34% chance of exploitation in 30 days (percentile 84, 2026-11-26)
- CWE
- CWE-121, CWE-119
- Modified
Description
A vulnerability was found in D-Link DIR-513 1.0. It has been rated as critical. Affected by this issue is the function sprintf of the file /goform/formLanSetupRouterSettings of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| D-Link DIR-513 | 1.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-7909. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-7909.md Affected: D-Link DIR-513 1.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for D-Link DIR-513: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Articles
FAQ
Is CVE-2025-7909 being exploited?
There is no confirmed exploitation: CVE-2025-7909 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.34% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-7909?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2025-7909?
D-Link DIR-513 1.0.
Is there a fix for CVE-2025-7909?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-7909?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.