# CVE-2025-7742: Authentication Bypass in LG Innotek Camera

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.3
- **CVSS:** 8.3 (v4.0, CNA) `CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: High; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: Low; Availability impact: Low; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.87% (percentile 56, 2026-11-26)
- **CWE:** CWE-288
- **Published:** 2025-07-24T23:28:32.443Z
- **Modified:** 2026-06-17T10:05:34.013Z

## Who should check

- Anyone running LG Innotek Camera Model LNV5110R All

## Description

An authentication vulnerability exists in the LG Innotek camera model LNV5110R firmware that allows a malicious actor to upload an HTTP POST request to the devices non-volatile storage. This action may result in remote code execution that allows an attacker to run arbitrary commands on the target device at the administrator privilege level.

## Affected and fixed versions

- LG Innotek Camera Model LNV5110R: All (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-7742. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-7742.md
Affected: LG Innotek Camera Model LNV5110R All
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for LG Innotek Camera Model LNV5110R: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-7742 being exploited?

There is no confirmed exploitation: CVE-2025-7742 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.87% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-7742?

High: CVSS 8.3 (v4.0, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2025-7742?

LG Innotek Camera Model LNV5110R All.

### Is there a fix for CVE-2025-7742?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-7742?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-advisories/icsa-25-205-04>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-7742>

HTML: <https://flawdb.com/CVE-2025-7742> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-7742>