CVE-2025-7705
Authentication bypass due to compatibility mode enabled by default
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running ABB Switch Actuator 4 DU-83330 All Versions
- Anyone running ABB Switch actuator, door/light 4 DU -83330-500 All Versions
Vulnerability facts
- Affected
- ABB Switch Actuator 4 DU-83330 All Versions; ABB Switch actuator, door/light 4 DU -83330-500 All Versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.6 (v4.0, CNA)CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 0.38% chance of exploitation in 30 days (percentile 24, 2026-11-26)
- CWE
- CWE-489
- Modified
Description
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-7705. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-7705.md Affected: ABB Switch Actuator 4 DU-83330 All Versions; ABB Switch actuator, door/light 4 DU -83330-500 All Versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-7705 being exploited?
There is no confirmed exploitation: CVE-2025-7705 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.38% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-7705?
High: CVSS 8.6 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-7705?
ABB Switch Actuator 4 DU-83330 All Versions; ABB Switch actuator, door/light 4 DU -83330-500 All Versions.
Is there a fix for CVE-2025-7705?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-7705?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.