CVE-2025-7639
AVEVA Enterprise SCADA Deserialization of Untrusted Data
Mitigation
- Vendor workaround: Defensive Measures and General Considerations
- The following general defensive measures are recommended:
- - Audit devices, network topology, and perimeter defences to ensure all applicable security best practices from AVEVA’s Enterprise SCADA Reference System Architecture are adhered to.
- - Audit assigned permissions to ensure that only trusted users are given https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html
- - Disallow BLT Test clients in production environments.
- For additional details on defensive measures, please refer to Section 5 of KB117814 “AVEVA Midstream Product Bulletin – Removal of Binary Formatter” https://softwaresupportsp.aveva.com/en-US/knowledge/details/000117814 .
Who should check
- Anyone running AVEVA Enterprise SCADA 2025; >= 2024, <= 2024 SP1 P01; >= 2023, <= 2023 SP1; >= 2022, <= 2022 SP2 P2; <= 2021 SP2 P5
- Anyone running AVEVA Enterprise SCADA HMI 2024; <= 2023_P1; 2024 R2
- Anyone running AVEVA Pipeline Operations for Gas/Liquids (versions: see the vendor advisory)
- Anyone running AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media) (versions: see the vendor advisory)
- Anyone running AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media) (versions: see the vendor advisory)
- Anyone running AVEVA Measurement Advisor (versions: see the vendor advisory)
Vulnerability facts
- Affected
- AVEVA Enterprise SCADA 2025; >= 2024, <= 2024 SP1 P01; >= 2023, <= 2023 SP1; >= 2022, <= 2022 SP2 P2; <= 2021 SP2 P5; AVEVA Enterprise SCADA HMI 2024; <= 2023_P1; 2024 R2; AVEVA Pipeline Operations for Gas/Liquids; AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media); AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media); AVEVA Measurement Advisor
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 6.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: Low
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.57% chance of exploitation in 30 days (percentile 41, 2026-11-26)
- CWE
- CWE-502
- Modified
Description
The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps".
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| AVEVA Enterprise SCADA | 2025; >= 2024, <= 2024 SP1 P01; >= 2023, <= 2023 SP1; >= 2022, <= 2022 SP2 P2; <= 2021 SP2 P5 | — | cvelist |
| AVEVA Enterprise SCADA HMI | 2024; <= 2023_P1; 2024 R2 | — | cvelist |
| AVEVA Pipeline Operations for Gas/Liquids | — | — | cvelist |
| AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media) | — | — | cvelist |
| AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media) | — | — | cvelist |
| AVEVA Measurement Advisor | — | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-7639. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-7639.md Affected: AVEVA Enterprise SCADA 2025; >= 2024, <= 2024 SP1 P01; >= 2023, <= 2023 SP1; >= 2022, <= 2022 SP2 P2; <= 2021 SP2 P5; AVEVA Enterprise SCADA HMI 2024; <= 2023_P1; 2024 R2; AVEVA Pipeline Operations for Gas/Liquids; AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media); AVEVA Pip… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for AVEVA Enterprise SCADA, AVEVA Enterprise SCADA HMI, AVEVA Pipeline Operations for Gas/Liquids, AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media), AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media), AVEVA Measurement Advisor: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-7639 being exploited?
There is no confirmed exploitation: CVE-2025-7639 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.57% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-7639?
Medium: CVSS 6.1 (v4.0, scored by CNA). Remote, login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2025-7639?
AVEVA Enterprise SCADA 2025; >= 2024, <= 2024 SP1 P01; >= 2023, <= 2023 SP1; >= 2022, <= 2022 SP2 P2; <= 2021 SP2 P5; AVEVA Enterprise SCADA HMI 2024; <= 2023_P1; 2024 R2; AVEVA Pipeline Operations for Gas/Liquids; AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media); AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media); AVEVA Measurement Advisor.
Is there a fix for CVE-2025-7639?
No fixed version is listed in the sources yet. Vendor workaround: Defensive Measures and General Considerations The following general defensive measures are recommended: - Audit devices, network topology, and perimeter defences to ensure all applicable security best practices from AVEVA’s Enterprise SCADA Reference System Architecture are adhered to. - Audit assigned permissions to ensure that only trusted users are given https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html - Disallow BLT Test clients in production environments. For additional details on defensive measures, please refer to Section 5 of KB117814 “AVEVA Midstream Product Bulletin – Removal of Binary Formatter” https://softwaresupportsp.aveva.com/en-US/knowledge/details/000117814 .
How do I check if I'm affected by CVE-2025-7639?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.