CVE-2025-71453
vtenext before 25.02.2 Reflected XSS via widgetInfoList in HomeWidgetBlockList
Mitigation
- Upgrade vtenext to 25.02.2 or later.
Who should check
- Anyone running vtenext < 25.02.2
Vulnerability facts
- Affected
- vtenext < 25.02.2
- Fixed in
- vtenext 25.02.2
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: Active
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: None
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: None
- EPSS
- 0.34% chance of exploitation in 30 days (percentile 20, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
vtenext before 25.02.2 contains a reflected cross-site scripting vulnerability in modules/Home/HomeWidgetBlockList.php that echoes unsanitized widgetId keys from the widgetInfoList JSON parameter. Attackers can induce a logged-in user to submit a crafted POST request with HTML in widgetId keys, executing JavaScript in the victim's vtenext session.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| vtenext | < 25.02.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-71453. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-71453.md Affected: vtenext < 25.02.2 Fixed in: vtenext 25.02.2 Steps: 1. Search this machine and project for vtenext: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2025-71453 being exploited?
There is no confirmed exploitation: CVE-2025-71453 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-71453?
Medium: CVSS 5.1 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-71453?
vtenext < 25.02.2.
Is there a fix for CVE-2025-71453?
Yes. Fixed in vtenext 25.02.2. Upgrade vtenext to 25.02.2 or later.
How do I check if I'm affected by CVE-2025-71453?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.