CVE-2025-69425
Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCE
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running RUCKUS Networks vRIoT IoT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA)
Vulnerability facts
- Affected
- RUCKUS Networks vRIoT IoT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA)
- Fixed in
- RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 10.0 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 1.29% chance of exploitation in 30 days (percentile 70, 2026-11-26)
- CWE
- CWE-306, CWE-798
- Modified
Description
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| RUCKUS Networks vRIoT IoT Controller | >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA) | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-69425. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-69425.md Affected: RUCKUS Networks vRIoT IoT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA) Fixed in: RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0 Steps: 1. Search this machine and project for RUCKUS Networks vRIoT IoT Controller: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-69425 being exploited?
There is no confirmed exploitation: CVE-2025-69425 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.29% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-69425?
Critical: CVSS 10.0 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-69425?
RUCKUS Networks vRIoT IoT Controller >= 2.3.0.0 (GA), < 3.0.0.0 (GA); >= 2.3.1.0 (MR), < 3.0.0.0 (GA); >= 2.4.0.0 (GA), < 3.0.0.0 (GA).
Is there a fix for CVE-2025-69425?
Yes. Fixed in RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0, RUCKUS Networks vRIoT IoT Controller 3.0.0.0. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-69425?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.