CVE-2025-6625
CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP c…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric Modicon M340 All versions
- Anyone running Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module All versions
- Anyone running Schneider Electric BMXNGD0100: M580 Global Data module All versions
- Anyone running Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules All versions
- Anyone running Schneider Electric BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module Versions prior to 3.60
- Anyone running Schneider Electric BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to 6.80
Vulnerability facts
- Affected
- Schneider Electric Modicon M340 All versions; Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module All versions; Schneider Electric BMXNGD0100: M580 Global Data module All versions; Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules All versions; Schneider Electric BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module Versions prior to 3.60; Schneider Electric BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to 6.80
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.72% chance of exploitation in 30 days (percentile 50, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric Modicon M340 | All versions | — | cvelist |
| Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module | All versions | — | cvelist |
| Schneider Electric BMXNGD0100: M580 Global Data module | All versions | — | cvelist |
| Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules | All versions | — | cvelist |
| Schneider Electric BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module | Versions prior to 3.60 | — | cvelist |
| Schneider Electric BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast module | Versions prior to 6.80 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-6625. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-6625.md Affected: Schneider Electric Modicon M340 All versions; Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module All versions; Schneider Electric BMXNGD0100: M580 Global Data module All versions; Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules All versions; Schneider Electr… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric Modicon M340, Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module, Schneider Electric BMXNGD0100: M580 Global Data module, Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules, Schneider Electric BMXNOE0100: Modbus/TCP Ethernet Modicon M340 modu…: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-6625 being exploited?
There is no confirmed exploitation: CVE-2025-6625 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.72% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-6625?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-6625?
Schneider Electric Modicon M340 All versions; Schneider ELectric BMXNOR0200H: Ethernet / Serial RTU Module All versions; Schneider Electric BMXNGD0100: M580 Global Data module All versions; Schneider Electric BMXNOC0401: Modicon M340 X80 Ethernet Communication modules All versions; Schneider Electric BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module Versions prior to 3.60; Schneider Electric BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to 6.80.
Is there a fix for CVE-2025-6625?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-6625?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.