# CVE-2025-66051: Path traversal in Vivotek IP7137 cameras

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.9
- **CVSS:** 6.9 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: High; User interaction: None; Confidentiality impact: High; Integrity impact: None; Availability impact: None; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, login needed
- **EPSS:** 1.24% (percentile 69, 2026-11-26)
- **CWE:** CWE-22
- **Published:** 2026-01-09T11:54:09.170Z
- **Modified:** 2026-06-17T09:56:14.760Z

## Who should check

- Anyone running Vivotek IP7137 0200a

## Description

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

## Affected and fixed versions

- Vivotek IP7137: 0200a (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-66051. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-66051.md
Affected: Vivotek IP7137 0200a
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Vivotek IP7137: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-66051 being exploited?

There is no confirmed exploitation: CVE-2025-66051 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.24% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-66051?

Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, login needed.

### Which versions are affected by CVE-2025-66051?

Vivotek IP7137 0200a.

### Is there a fix for CVE-2025-66051?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-66051?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert.pl/posts/2026/01/CVE-2025-66049>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-66051>

HTML: <https://flawdb.com/CVE-2025-66051> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-66051>