CVE-2025-61977
AutomationDirect Productivity Suite Weak Password Recovery Mechanism for Forgotten Password
Mitigation
- Vendor workaround: AutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to the latest version:
- * Physically disconnect the PLC from any external networks, including the internet, local area networks (LANs), and other interconnected systems.
- * Configure network segmentation to isolate the PLC from other devices and systems within the organization.
- * Implement firewall rules or network access control (NAC) policies to block incoming and outgoing traffic to the PLC.
- * Please refer to AutomationDirect's security considerations https://support.automationdirect.com/docs/securityconsiderations.pdf for additional information.
- * If you have any questions regarding this issue, please contact AutomationDirect Technical Support at 770-844-4200 or 800-633-0405 for further assistance.
Who should check
- Anyone running AutomationDirect Productivity Suite <= SW V4.2.1.9
- Anyone running AutomationDirect Productivity 3000 P3-622 CPU <= SW V4.2.1.9
- Anyone running AutomationDirect Productivity 3000 P3-550E CPU <= SW V4.2.1.9
- Anyone running AutomationDirect Productivity 3000 P3-530 CPU <= SW v4.4.1.19
- Anyone running AutomationDirect Productivity 2000 P2-622 CPU <= SW v4.4.1.19
- Anyone running AutomationDirect Productivity 2000 P2-550 CPU <= SW v4.4.1.19
- Anyone running AutomationDirect Productivity 1000 P1-550 CPU <= SW v4.4.1.19
- Anyone running AutomationDirect Productivity 1000 P1-540 CPU < SW v4.4.1.19
Vulnerability facts
- Affected
- AutomationDirect Productivity Suite <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-622 CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-550E CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-530 CPU <= SW v4.4.1.19; AutomationDirect Productivity 2000 P2-622 CPU <= SW v4.4.1.19; AutomationDirect Productivity 2000 P2-550 CPU <= SW v4.4.1.19; AutomationDirect Productivity 1000 P1-550 CPU <= SW v4.4.1.19; AutomationDirect Productivity 1000 P1-540 CPU < SW v4.4.1.19
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.3 (v4.0, CNA)CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: High
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.19% chance of exploitation in 30 days (percentile 5, 2026-11-26)
- CWE
- CWE-640
- Modified
Description
A weak password recovery mechanism for forgotten password vulnerability was discovered in Productivity Suite software version v4.4.1.19. The vulnerability allows an attacker to decrypt an encrypted project by answering just one recovery question.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| AutomationDirect Productivity Suite | <= SW V4.2.1.9 | — | cvelist |
| AutomationDirect Productivity 3000 P3-622 CPU | <= SW V4.2.1.9 | — | cvelist |
| AutomationDirect Productivity 3000 P3-550E CPU | <= SW V4.2.1.9 | — | cvelist |
| AutomationDirect Productivity 3000 P3-530 CPU | <= SW v4.4.1.19 | — | cvelist |
| AutomationDirect Productivity 2000 P2-622 CPU | <= SW v4.4.1.19 | — | cvelist |
| AutomationDirect Productivity 2000 P2-550 CPU | <= SW v4.4.1.19 | — | cvelist |
| AutomationDirect Productivity 1000 P1-550 CPU | <= SW v4.4.1.19 | — | cvelist |
| AutomationDirect Productivity 1000 P1-540 CPU | < SW v4.4.1.19 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-61977. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-61977.md Affected: AutomationDirect Productivity Suite <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-622 CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-550E CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-530 CPU <= SW v4.4.1.19; AutomationDirect Productivity 2000 P2-622 CPU <= SW v4.4.1.… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for AutomationDirect Productivity Suite, AutomationDirect Productivity 3000 P3-622 CPU, AutomationDirect Productivity 3000 P3-550E CPU, AutomationDirect Productivity 3000 P3-530 CPU, AutomationDirect Productivity 2000 P2-622 CPU, AutomationDirect Productivity 2000 P2-550 CPU: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-61977 being exploited?
There is no confirmed exploitation: CVE-2025-61977 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.19% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-61977?
High: CVSS 7.3 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2025-61977?
AutomationDirect Productivity Suite <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-622 CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-550E CPU <= SW V4.2.1.9; AutomationDirect Productivity 3000 P3-530 CPU <= SW v4.4.1.19; AutomationDirect Productivity 2000 P2-622 CPU <= SW v4.4.1.19; AutomationDirect Productivity 2000 P2-550 CPU <= SW v4.4.1.19; AutomationDirect Productivity 1000 P1-550 CPU <= SW v4.4.1.19; AutomationDirect Productivity 1000 P1-540 CPU < SW v4.4.1.19.
Is there a fix for CVE-2025-61977?
No fixed version is listed in the sources yet. Vendor workaround: AutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to the latest version: * Physically disconnect the PLC from any external networks, including the internet, local area networks (LANs), and other interconnected systems. * Configure network segmentation to isolate the PLC from other devices and systems within the organization. * Implement firewall rules or network access control (NAC) policies to block incoming and outgoing traffic to the PLC. * Please refer to AutomationDirect's security considerations https://support.automationdirect.com/docs/securityconsiderations.pdf for additional information. * If you have any questions regarding this issue, please contact AutomationDirect Technical Support at 770-844-4200 or 800-633-0405 for further assistance.
How do I check if I'm affected by CVE-2025-61977?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.