# CVE-2025-59967: Junos OS Evolved: ACX7024, ACX7024X, ACX7100-32C,  ACX7100-48L, ACX7348, ACX7509: When specific valid multicast traffic is received on the L3 interface on a vulnerable device evo-pfemand crashes and restarts

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.1
- **CVSS:** 7.1 (v4.0, CNA) `CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:A/V:C/RE:M/U:Green`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: None; Integrity impact: None; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: Low; AU: Y; R: A; V: C; RE: M; U: Green
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.31% (percentile 16, 2026-11-26)
- **CWE:** CWE-476
- **Published:** 2025-10-09T15:47:10.103Z
- **Modified:** 2026-10-08T13:10:00.200Z

## Who should check

- Anyone running Juniper Networks Junos OS Evolved \>= 23.2R2-EVO, \< 23.2R2-S4-EVO; \>= 23.4R1-EVO, \< 23.4R2-EVO

## Description

A NULL Pointer Dereference vulnerability in the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved on ACX7024, ACX7024X, ACX7100-32C, ACX7100-48L, ACX7348, ACX7509 devices allows an unauthenticated, adjacent attacker to cause a 

Denial-of-Service (DoS).

Whenever specific valid multicast traffic is received on any layer 3 interface the evo-pfemand process crashes and restarts.

Continued receipt of specific valid multicast traffic results in a sustained Denial of Service (DoS) attack. 
This issue affects Junos OS Evolved on ACX7024, ACX7024X, ACX7100-32C, ACX7100-48L, ACX7348, ACX7509: 



  \*  from 23.2R2-EVO before 23.2R2-S4-EVO, 
  \*  from 23.4R1-EVO before 23.4R2-EVO.


This issue affects IPv4 and IPv6. 

This issue does not affect  Junos OS Evolved ACX7024, ACX7024X, ACX7100-32C, ACX7100-48L, ACX7348, ACX7509 versions before 23.2R2-EVO.

## Affected and fixed versions

- Juniper Networks Junos OS Evolved: \>= 23.2R2-EVO, \< 23.2R2-S4-EVO; \>= 23.4R1-EVO, \< 23.4R2-EVO (cvelist)

## Mitigation

- Upgrade Junos OS Evolved to 23.4R2-EVO or later.
- Vendor workaround: There are no known workarounds for this issue.
- To reduce the risk of exploitation, enable access control lists (ACLs) and other filtering mechanisms to limit access to the device only from trusted hosts.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-59967. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-59967.md
Affected: Juniper Networks Junos OS Evolved >= 23.2R2-EVO, < 23.2R2-S4-EVO; >= 23.4R1-EVO, < 23.4R2-EVO
Fixed in: Juniper Networks Junos OS Evolved 23.2R2-S4-EVO, Juniper Networks Junos OS Evolved 23.4R2-EVO

Steps:
1. Search this machine and project for Juniper Networks Junos OS Evolved: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-59967 being exploited?

There is no confirmed exploitation: CVE-2025-59967 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.31% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-59967?

High: CVSS 7.1 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-59967?

Juniper Networks Junos OS Evolved \>= 23.2R2-EVO, \< 23.2R2-S4-EVO; \>= 23.4R1-EVO, \< 23.4R2-EVO.

### Is there a fix for CVE-2025-59967?

Yes. Fixed in Juniper Networks Junos OS Evolved 23.2R2-S4-EVO, Juniper Networks Junos OS Evolved 23.4R2-EVO. Upgrade Junos OS Evolved to 23.4R2-EVO or later. Vendor workaround: There are no known workarounds for this issue. To reduce the risk of exploitation, enable access control lists (ACLs) and other filtering mechanisms to limit access to the device only from trusted hosts.

### How do I check if I'm affected by CVE-2025-59967?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://supportportal.juniper.net/JSA103156>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-59967>

HTML: <https://flawdb.com/CVE-2025-59967> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-59967>