Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2025-59778

HIGH 7.7EPSS 43%

VELOS partition container network vulnerability

Mitigation

  • Upgrade F5OS - Chassis to 1.6.4 or later.

Who should check

  • Anyone running F5OS - Chassis >= 1.8.0, < 1.8.2; >= 1.6.0, < 1.6.4

Vulnerability facts

Affected
F5OS - Chassis >= 1.8.0, < 1.8.2; >= 1.6.0, < 1.6.4
Fixed in
F5OS - Chassis 1.8.2, F5OS - Chassis 1.6.4
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: Low
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: High
EPSS
0.61% chance of exploitation in 30 days (percentile 43, 2026-11-26)
CWE
CWE-770
Published
Modified

Description

When the Allowed IP Addresses feature is configured on the F5OS-C partition control plane, undisclosed traffic can cause multiple containers to terminate.   Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Affected and fixed versions

Package / productAffectedFixedSource
F5OS - Chassis>= 1.8.0, < 1.8.2; >= 1.6.0, < 1.6.4—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2025-59778. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-59778.md
Affected: F5OS - Chassis >= 1.8.0, < 1.8.2; >= 1.6.0, < 1.6.4
Fixed in: F5OS - Chassis 1.8.2, F5OS - Chassis 1.6.4

Steps:
1. Search this machine and project for F5OS - Chassis: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2025-59778 being exploited?

There is no confirmed exploitation: CVE-2025-59778 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.61% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2025-59778?

High: CVSS 7.7 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2025-59778?

F5OS - Chassis >= 1.8.0, < 1.8.2; >= 1.6.0, < 1.6.4.

Is there a fix for CVE-2025-59778?

Yes. Fixed in F5OS - Chassis 1.8.2, F5OS - Chassis 1.6.4. Upgrade F5OS - Chassis to 1.6.4 or later.

How do I check if I'm affected by CVE-2025-59778?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors