# CVE-2025-5747: WOLFBOX Level 2 EV Charger MCU Command Parsing Misinterpretation of Input Remote Code Execution Vulnerability

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.0
- **CVSS:** 8.0 (v3.0, CNA) `CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: Low; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.64% (percentile 45, 2026-11-26)
- **CWE:** CWE-115
- **Published:** 2025-06-06T15:30:59.842Z
- **Modified:** 2026-06-17T09:48:40.843Z

## Who should check

- Anyone running WOLFBOX Level 2 EV Charger 3.1.17 (main), 1.2.6 (MCU)

## Description

WOLFBOX Level 2 EV Charger MCU Command Parsing Misinterpretation of Input Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installatons of WOLFBOX Level 2 EV Charger devices. Authentication is required to exploit this vulnerability.

The specific flaw exists within the handling of command frames received by the MCU. When parsing frames, the process does not properly detect the start of a frame, which can lead to misinterpretation of input. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26501.

## Affected and fixed versions

- WOLFBOX Level 2 EV Charger: 3.1.17 (main), 1.2.6 (MCU) (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-5747. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-5747.md
Affected: WOLFBOX Level 2 EV Charger 3.1.17 (main), 1.2.6 (MCU)
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for WOLFBOX Level 2 EV Charger: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-5747 being exploited?

There is no confirmed exploitation: CVE-2025-5747 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.64% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-5747?

High: CVSS 8.0 (v3.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-5747?

WOLFBOX Level 2 EV Charger 3.1.17 (main), 1.2.6 (MCU).

### Is there a fix for CVE-2025-5747?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-5747?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.zerodayinitiative.com/advisories/ZDI-25-326/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-5747>

HTML: <https://flawdb.com/CVE-2025-5747> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-5747>