CVE-2025-5022
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” P…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Mitsubishi Electric Corporation PV-DR004J All versions
- Anyone running Mitsubishi Electric Corporation PV-DR004JA All versions
Vulnerability facts
- Affected
- Mitsubishi Electric Corporation PV-DR004J All versions; Mitsubishi Electric Corporation PV-DR004JA All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.5 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.33% chance of exploitation in 30 days (percentile 19, 2026-11-26)
- CWE
- CWE-521
- Modified
Description
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Mitsubishi Electric Corporation PV-DR004J | All versions | — | cvelist |
| Mitsubishi Electric Corporation PV-DR004JA | All versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-5022. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-5022.md Affected: Mitsubishi Electric Corporation PV-DR004J All versions; Mitsubishi Electric Corporation PV-DR004JA All versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Mitsubishi Electric Corporation PV-DR004J, Mitsubishi Electric Corporation PV-DR004JA: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-5022 being exploited?
There is no confirmed exploitation: CVE-2025-5022 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.33% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-5022?
Medium: CVSS 6.5 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-5022?
Mitsubishi Electric Corporation PV-DR004J All versions; Mitsubishi Electric Corporation PV-DR004JA All versions.
Is there a fix for CVE-2025-5022?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-5022?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.